The building is designed to withstand the dead load (DL) of
the structure plus a specified live load (LL) and wind load (WL).
|
2. |
Vardhman Steel standard design is based on 0.75 kN/m2 liveload and a 30-50 m/s wind speed.
|
3. |
Collateral loads, if any, must be specified by the customer
at the time of request for quotation.
|
4. |
Where snow load is specified, the higher value of either the
snow load (in lieu of live load) or the live load will be used in
load combinations to produce the maximum adverse effect on
the structure. Snow load and live load are not additive in load
combinations.
|
5. |
Load combinations are in accordance with the requirements of
the 1996 "Low Rise Building Systems Manual" published by MBMA.
|
6. |
Other loads and load combinations can be accommodated and
must be specified at the time of request for quotation. |