1). What is the main difference between current conventional steelconstruction in India and the VARDHMAN PEB systems of construction? |
VARDHMAN PEB Systems delivers the complete steel building package to
the site from a single supplier as a fully finished product. This
includes the structural steel, cladding system and building accessories. Site
erection is fast and simple - just bolting together the various
building components as per the erection drawings provided. No site fabrication
or welding is involved. This result in significant saving in
construction time and superior quality compared to conventional steel
construction.
PEB System is highly efficient in design due to synergy between
building components. Primary members are made of tapered built-up sections and
roof/wall secondary members from cold rolled sections designed as
continuous beams. High strength steel is used. All structural elements are
fully optimized by the computerized design program.
|
| 2). What are the advantages of VARDHMAN PEB System? |
Reduction in project cost: Cost savings primarily result from above
time saving on the Project. This also results in earlier realization of
revenue to owner on a commercial project.
Saving in construction time: About 30-50% time saving in total project
schedule due to fast delivery and quick site erection.
Low Maintenance: High quality paint systems are available for steel and
cladding to be provided along with maintenance free service life.
Large clear spans: Buildings can be supplied in clear spans up to 90
meter, particularly suitable for aircraft hangers, sports facilities,
etc…
Flexibility in expansion: Buildings can be designed for future
expansion in length, width and height.
Energy efficiency: Buildings are supplied with roof and wall insulation
to reduce energy costs and improve comfort level inside the building.
Superior quality: Complete manufacturing is done in plant as per ISO
9001 quality assurance standards.
|
| 3). Are PEB systems suitable for Indian and Overseas weather conditions? |
Yes, Vardhman has supplied buildings for a range of weather conditions
including snow conditions, high desert temperatures, high humidity,
proximity to sea, heavy rainfall, cyclone wind speeds, seismic loads, etc…
Based on the ambient conditions at site and building usage, we will
design and manufacture the building to the specified requirements.
|
| 4). Do you provide a complete building package? What about flooring? |
We can supply the complete steel building including standard
accessories. Accessories that are not manufactured by Vardhman can be supplied as
buy outs (Rolled Up Doors, Cranes etc.) and can be included in
Vardhman’s scope of supply. For mezzanine floors we will provide the steel
framing and steel deck. If the flooring is of pre-cast concrete panels,
we will provide the floor supports beams.
|
| 5). Is there any limitation on the minimum size of building? |
No, Vardhman Building System can provide a small car park shed to a
massive industrial complex comprising thousand of square meters of covered
area.
|
| 6). How much is the saving in foundations? |
The saving would be basically due to less number of column foundations
due to large spans and bay spacing plus reduction in column reactions
due to less dead load of steel. It is not possible to quantify the cost
savings as it would vary by type of project. Pre-Engineered Building
utilize pierced (column) beam as a general rule which results in lighter
foundation.
|
| 7). How do IS codes compare with American codes? |
IS codes are of an old vintage and design and serviceability criteria
are based on older materials and do not take into account cost saving
with finding high strength materials. We recommend accepting latest
International design codes as these have been used literally in millions of
PEB buildings in North America and other parts of the world and have a
proven record of safety. Each year in the US alone, about 2 Million
tons of PEBs are sold based on International codes. Also American codes
are continually updated based on the latest research findings. Hence
these codes result in a more economical and safe building. IS codes are
more conservative and will increase weight and cost without adding value
to the building. However, if a client insists on IS codes we will design
and supply in accordance with these or any other codes.
|
| 8). What is the thickness of your sheeting? |
Our Standard sheeting thickness for roof/wall cladding is 26G. These
are available in various colors. Other thicknesses can be offered too on
special order with comparatively longer delivery time period.
|
| 9). How do I get quote for a VARDHMAN PEB? |
The inquiry should be sent to our sales office in your region. We will
design and price each project based on the specifications provided. We
will submit a proposal offer with detailed scope of supply, price,
delivery and payment terms. On request, Proposal Drawings with column
reactions are provided.
|
|